- USD
- CNY
- HKD
- EUR
- العربية
- čeština
- dansk
- Deutsch
- Ελληνικά
- English
- Español
- Français
- ic
- Italiano
- Netherlands
- norsk Språk
- język polski
- pt
- Português
- 中文


REL-MR-24DC/21HC
Subscribe to get pricesModel: REL-MR-24DC/21HC
Order No: 2961312
SKU: 10000116961101
Condition: New Sealed Under Guarantee
Size: 25.00 mm,15.00 mm,29.00 mm
Weight: 20.00g
Product Selection Engineer:ChuFuHua
Brief Introduction
REL-MR-24DC/21HC
Product Type: Single Relay.Electrical characteristicsInput data: Rated input voltage of 24V DC, input voltage range from 15.6V DC to 57.6V DC, and drive mode is monostable and non-polarized. At the rated input voltage, the typical input current is 17mA, the typical response time is 7ms, the typical release time is 3ms, and the coil resistance is 1440Ω±10% at 20°C.Output data: 1 changeover contact of the contact switching type, single contact of the switching contact type, AgNi of the contact material. The maximum switching voltage is 250V AC/DC, the minimum switching voltage is 12V (at 10mA), the limited continuous current is 16A, the maximum inrush current is 50A (20ms), and the minimum switching current is 10mA (at 12V). The switching capacitances are 2A at 24V, DC13, 0.2A at 110V, DC13, 0.2A at 250V, DC13, 6A at 24V, AC15, 6A at 120V, AC15, and 6A at 250V, AC15. UL 508 compliant motor loads are 1/2HP, 120V AC (normally open contacts), 1HP, 240V AC (normally open contacts), 1/3HP, 120V AC (normally closed contacts), 3/4HP, 240V AC (normally closed contacts), 1/4HP, 200-250V AC.
Description
Electrical characteristics
Input data: Rated input voltage of 24V DC, input voltage range from 15.6V DC to 57.6V DC, and drive mode is monostable and non-polarized. At the rated input voltage, the typical input current is 17mA, the typical response time is 7ms, the typical release time is 3ms, and the coil resistance is 1440Ω±10% at 20°C.
Output data: 1 changeover contact of the contact switching type, single contact of the switching contact type, AgNi of the contact material. The maximum switching voltage is 250V AC/DC, the minimum switching voltage is 12V (at 10mA), the limited continuous current is 16A, the maximum inrush current is 50A (20ms), and the minimum switching current is 10mA (at 12V). The switching capacitances are 2A at 24V, DC13, 0.2A at 110V, DC13, 0.2A at 250V, DC13, 6A at 24V, AC15, 6A at 120V, AC15, and 6A at 250V, AC15. UL 508 compliant motor loads are 1/2HP, 120V AC (normally open contacts), 1HP, 240V AC (normally open contacts), 1/3HP, 120V AC (normally closed contacts), 3/4HP, 240V AC (normally closed contacts), 1/4HP, 200-250V AC.
Subscription successful
Price list will be sent to you by email within 24hrs.